Electronic water treatment- automated devices

 

EUV 50 AI - EUV 1000 AI

Devices EUV 50 AI - EUV 1000 AI are designed to be used when the flow rate of the water fluctuates in a wide range irregularly. Built-in water meter supplemented by a sensor is checking the flow rate in regular intervals and automatically sets an optimal mode for current flow rate.

 

 

 

 

 

 

 

 

 

How to install the device:

Preparation of hot non-potable water for larger boiler rooms and heat exchanger stations


Automatic EUV installation
Data in brackets are valid for smaller pipe diameters and smaller flow rates

 

Basic technical parameters of EUV xx AI- type devices

Type Flow rate [m3/hod] Max. pipe diameter Dimensions [mm] Power [VA]
inner [mm-inch] outer [mm]
EUV 50 AI 0,2 - 11 50 (2 ") 60 275x220x140 8
EUV 65 AI 0,3 - 18 65 (2 1/2 ") 76 275x220x140 8
EUV 80 AI 0,5 - 27 80 (3 ") 89 275x220x140 8
EUV 100 AI 0,8 - 42 100 (4 ") 115 275x220x140 8
EUV 125 AI 1,4 - 66 125 (5 ") 140 275x220x140 10
EUV 150 AI 2,0 - 100 150 (6 ") 166 275x220x140 10
EUV 200 AI 3,2 - 170 200 (8 ") 219 275x220x140 10
EUV 250 AI 6,0 - 270 250 (10 ") 273 275x220x140 10
EUV 300 AI 8,0 - 380 300 (12 ") 324 275x220x140 10
EUV 400 AI 13,0 - 680 400 (16 ") 430 370x275x140 16
EUV 500 AI 24,0 - 1100 500 (20 ") 535 370x275x140 16

 

Installation of EUV xx AI- type devices

 

Automatic EUV

 

 

Built-in flow rate sensors for EUV xx AI

Flow rate sensor

Basic technical parameters of the impulse flow rate sensors

Sensor

IR – reflective light beam according to DIN 19234

Specification

Supply voltage

8,2 V DC (from EUV xx AI)

 

Current while reflecting

1,2 mA

 

Current when not reflecting

2,1 mA

Constant

DN 40 - 125

1 impulse / litre

 

DN 150 - 300

1 impulse / 10 litres