Electronic water treatment- technical parameters

General specification of AntiCa++ devices

  • Voltage 230 V, 50 Hz, different power supply possible if required
  • Electricity consumption 3.5 to 16 VA depending on the type of device
  • At least 20 years service life
  • Working temperature 0°C to +40°C (can be adjusted to -40°C to +40°C if necessary)
  • Working cycle can be set to daily or weekly for the type T device
  • Loading capacity of signalization is max. 15 W, 1 A and 125 V

Warranty

Manufacturer guarantees 36 months warranty. During this period will be faulty product exchanged for a new one free of charge.
Devices fulfil requirements of electrical safety standard and electromagnetic compatibility with EMC according to:

  • Low Voltage Directive 73/23/EEC
  • EMC Directive 89/336/EEC

Devices meet the requirements of:

  • EN 61000-6-1
  • EN 61000-6-1
  • EN 60 335-1

Certificates:

  • CB / SK - 29
  • CB / SK - 30
  • CB / SK - 62
  • CB / SK - 66
  • РФСС № C-SK.АИ30.В.02774
  • TUV No. D 02 07 47054 001

Basic technical parameters of the devices:

Power supply

230V, 50-60 Hz

Air temperature

+1 Až 50 ° C

Temperature in the pipe

 

EUV xx DOM

max. 70 ° C

Other types

max. 150 ° C

Coil length

max. 1,5 m

Power cable length

 

EUV xx DOM

max. 1,5 m

Other types

max. 2,2 m

Weight of the EUV devices

 

EUV 15 - 25 DOM

0,5 kg

EUV 32 - 65 DOM

1kg

EUV 15 - 80 D

1kg

EUV 32 - 65 T

2,5 kg

EUV xx MI, TI, AI

from 5kg up

Energy consumption of EUV devices

 

EUV 15 - 50 DOM

2VA

EUV 65 - 80 DOM

5VA

EUV 10 - 50 D

5VA

EUV 65 - 80 D

6VA

EUV 32 T - 65 T

6VA

EUV 50 - 100 MI, TI, AI

8VA

EUV 125 - 300 MI, TI, AI

10VA

EUV 400 - 500 MI, TI, AI

16VA

Signalization of operation by contact

 

Loading capacity of relay

15W (ohmic load, max. 1A)

Max. voltage in the contacts

125V

Impulse flow rate sensor

 

Supply voltage

8,2 V DC (from EUV xx AI)

Current by reflexion

<1,2 mA

Current without reflexion

> 2,1 ma

Constant DN 50 - DN 125

1 impulse / litre

Constant DN 150 - DN 300

1 impulse / 10 litres

Constant DN 300 - DN 500

1 impulse / 100 litres

Current flow rate sensor

 

Current with zero flow rate

0mA (4mA)

Current with max. flow rate

20mA